FULLY AUTOMATIC (FA)This fully electric valve automatically changes itsposition based on electrical signal. When the Soli-Con® solenoid actuator is de
EXAMPLE: 2520FACMPS1FTEYL2520 FAC MP S 1F TEY L1,2,3,4 5,6,7 8,9 10 11,12 13 14 15 16,17 and/or 182520: 2-Way fully automatic rotary shaft type Soli-C
102500 SERIES VALVE SPECIFICATION FORMLaurence Products, Electric On / OffI have (or anticipate) a requirement for an electrically actuated valve as f
11SERIES 500, 550 & 600 – 2-WAY SHUTOFF TYPE (Fail Closed)SOLI-CON®VALVES2-WAY SHUTOFF VALVESROTARY SHAFT TYPESERIES 500SCSERIES 550SCSERIES 600SC
NEMA 1 • NEMA 2 • NEMA 3 • NEMA 4 • NEMA 4X • NEMA 12ACTUATOR ENCLOSUREFM APPROVED • EXPLOSION PROOFCLASS I, GROUPS B, C & D • CLASS II GROUPS E,
PRESSURES -FOR HIGHER PRESSURES -TEMPERATURES -PORT SIZES -TYPE CONNECTIONS -**STAINLESS STEEL, STEEL, & MONEL VALVES -CvFLOW FACTORS -SEE PAGE 4
DIMENSIONSAll above dimensions and weights are approximate forestimating purposes only.• Standard flanges are drilled per ANSI B16.5 orB16.24• Install
SERIES 700, 700HP, 800 – 2-WAY MANUALLY RESETSAFETY SHUTOFFSOLENOID VALVES– NO VOLTAGE RELEASE - Trip on Current Failure– NORMALLY CLOSED - Reset to O
CATALOG NUMBERPREFIXESFOR SERIES 700HP ADD “HP” TO SERIES 700 PREFIX ABOVEOPTIONAL FEATURES16
CATALOG NUMBER SUFFIXESORDERING DATA17
Questions?... SOLUTIONS FM & CE Approved Solenoid Isolatedfrom corrosive, hightemperature orflammable media No Minimum Pressureor flow requi
DIMENSIONSHORIZONTAL PIPE MOUNTING* For DC suffixes, dimension “B” is 1-1/2" less in most cases.- All above dimensions and weights are approximat
SERIES 750, 750HP, 850 – 2-WAY MANUALLY RESETFAIL OPENSOLENOID VALVESFor Fire Deluge - Emergency Dump, Vent, Discharge- Process Cooling– NO VOLTAGE RE
CATALOG NUMBERPREFIXESFOR SERIES 750HP ADD “HP” TO SERIES 750 PREFIX ABOVEOPTIONAL FEATURES20
CATALOG NUMBER SUFFIXESORDERING DATA21
DIMENSIONS* For DC suffixes, dimension “B” is slightly less in most cases.- All above dimensions and weights are approximate, for estimatingpurposes o
SERIES 1100, 1100HP, 1200 - 2-WAY MANUALLY RESETTRIP SHUTOFFSOLENOID VALVES– ELECTRICALLY TRIPPED - Trip upon Energization– NORMALLY CLOSED - Latch to
FOR SERIES 1100HP ADD “HP” TO SERIES 1100 PREFIX ABOVECATALOG NUMBERPREFIXESOPTIONAL FEATURES24
CATALOG NUMBER SUFFIXESORDERING DATA25
DIMENSIONS- All above dimensions and weights are approximate, for estimating purposes only. Dimensions are based onA.C. solenoid - (D.C. solenoid slig
SERIES 1150, 1150HP, 1250 - 2-WAY MANUALLY RESETMANUALLY RESET, ELECTRICALLY TRIPPEDNORMALLY OPEN, LATCH TO CLOSESERIES 1150SERIES 1250ROTARY SHAFT TY
RotaryOn-OffControlValvesRotaryOn-OffControlValvesHeatActuatedElectricActuatedPneumatic/HydraulicActuatedAPPLICATIONSDirty, viscous or unclean liquids
CATALOG NUMBERPREFIXESFOR SERIES 1150HP ADD “HP” TO SERIES 1150 PREFIX ABOVEOPTIONAL FEATURES28
CATALOG NUMBER SUFFIXESORDERING DATAPRESSURES29
DIMENSIONS- All above dimensions and weights are approximate, for estimating purposes only. Dimensions are based onA.C. solenoid - (D.C. solenoid slig
SERIES 3300 - 3-WAY ROTARY SHAFT TYPEDIRECT OPERATED - POPPET TYPESOLENOID VALVESFULLY ELECTRICAL (Automatic Reset)FLOW FORMSDIRECT OPERATED – POPPET
CATALOGNUMBERPREFIXESOPTIONAL FEATURES* For purposes of identifying alloy by chemical analysis32
CATALOG NUMBER SUFFIXESORDERING DATA33
34DIMENSIONS(in.) (AC voltage only)– All dimensions and weightsshown here are approximatefor estimating purposes only.– For dimensions for D.C.voltage
35SERIES 3400 & 3500 - 3-WAY MANUALLY RESETROTARY SHAFT TYPESOLENOIDVALVESDirect Operated - Poppet TypeMANUALLY RESET, ELECTRICALLY TRIPPEDSERIES
CATALOGNUMBERPREFIXESOPTIONAL FEATURES36
CATALOG NUMBER SUFFIXESORDERING DATAPRESSURES37
2It is solely the responsibility of the system designer and the user to select products and materials suitable for their specific applicationrequireme
DIMENSIONS38
SERIES CY500 & CY6002-WAY ROTARY SHAFT TYPECYLINDER OPERATED VALVENORMALLY CLOSED - OPENEND BY CYLINDERHorizontal or Vertical Pipe MountingLaurenc
VALVE BODY CANBE ROTATED 90º TOFOUR POSITIONSTO FACILITATEMOUNTINGFOR DIRECTIONOF FLOWSEE INSTRUCTIONSHEETALL FLANGES DRILLEDTO ANSI STANDARDSVALVECLO
41SOLI-CON®NEMA 4 Explosion Proof RATED VOLTAGE INRUSH/ “A” “B” “C” “D” “E” “F” MAX. MIN. MIN.FM Approved HOLDING1DIA Stroke Force2Hold2SCA ESCA 120 V
FM APPROVED EXPLOSION PROOFSOLENOID OPERATORS/ACTUATORSFor CLASS I, GROUPS A, B, C & D, Division 1 & 2 Areas andCLASS II, GROUPS E, F & G,
FM APPROVED EXPLOSION PROOFSOLENOID OPERATORS/ACTUATORSUNAUTHORIZED ALTERATIONS TO THESOLENOID ENCLOSURE VOIDS THE FMAPPROVAL AND THE PRODUCT WARRANTY
FM APPROVED EXPLOSION PROOFSOLENOID OPERATORS/ACTUATORSUNAUTHORIZED ALTERATIONS TO THESOLENOID ENCLOSURE VOIDS THE FMAPPROVAL AND THE PRODUCT WARRANTY
I have (or anticipate) a requirement for an actuator as follows:Quantity _____________________ A.C. D.C. Voltage____________ Hertz____________Summa
ELECTRIC ON-OFF CONTROL VALVESACTUATEDPOSITION(SOLENOIDENERGIZED)NORMALPOSITION(SOLENOIDDE-ENERGIZED)3-WAY FLOW FORMSABCABCABCABCABCABCABCABCFLOW FORM
ELECTRIC ON-OFF CONTROL VALVESSPEC SHEETI have (or anticipate) a requirement for an electrically actuated valve as follows:Quantity _________________P
32500 SERIESELECTRIC ACTUATED,FAST ACTING, PROCESS FLUID,SHUT-OFF VALVES
FIRE-CIDE®SERIES - HEAT ACTUATED SHUTOFF VALVEALL VALVES FACTORY MUTUAL SYSTEM APPROVED FOR EMERGENCY SHUT-OFFROTARY SHAFT DESIGNFIRE-CIDE®series valv
All dimensions (inches), weights (pounds)and Cv’s listed are approximate and are forestimating purposes only. All flanges aredrilled to ANSI B16.5. Va
NOTE: Fusible links are UL approved.Threaded ends are availablein1⁄2" to 2" only.FIRE-CIDE®2800 SERIES ORDERING CODE2820H2CMPS1FT12345678910
QUESTIONS? CALL LESLIE CONTROLS @ (813) 978-1000 PLEASE FAX COMPLETED FORM TO: (813) 977-0174I have (or anticipate) a requirement for a Fire Safety Sh
1700, 1700HP AND 1800 SERIES ORDERINGVALVE BODY INNER PARTS DISC CATALOG NUMBER PREFIXESBronze Stainless SteelRegrinding 1702 1702HP 1805Resilient 170
CATALOG PIPE FACE HORIZONTAL PIPE MOUNTINGNUMBER SIZE TOSUFFIX FACE BCDNETWEIGHT14 3" 6" 9" 3-3/4" 12 lb.18 1/2" 5-1/4 6 9-1/
ACTUATEDPOSITION(LATCHED)NORMALPOSITION(TRIPPED)3-WAY FLOW FORMSABCABCABCABCABCABCABCABCFLOW FORM M FLOW FORM N FLOW FORM O FLOW FORM PINLET AT A INLE
FIRE-SIDE®SERIES SPEC SHEETI have (or anticipate) a requirement for a Fire Safety Shut Off valve as follows:Quantity _________________Pipe Size ______
Notes:56
COMPRESSED AIR EXTRACTION VALVEFOR INDUSTRIAL GAS TURBINESATOMIZING AIR BYPASS VALVEFOR DUAL-FUELCOMBUSTION TURBINES RELIABILITY• Designed to take th
2500 SERIES - ELECTRICALLY ACTUATED SHUTOFF VALVEROTARY SHAFTFAST DELIVERY - This modular design provides thecapability to stock valve components that
2500 SERIES VALVEPISTON OPTIONSOPTION D - Direct Operated for Low PressuresThis series can be used for viscous or dirty fluids as well aslight liquids
2500 SERIES DIMENSIONSSize & Connections Max. Opening Diff. Press. (psi) DimensionsPipe/ NetPort Direct (D) Pilot (P) Semi-Direct (S) Wgt. ABCDSuf
2500 SERIES ACTUATORSSOLI-CON® SOLENOID ACTUATORSThe Soli-Con® solenoid actuator is a solid-state-controlled electric actuator, which effectivelyelimi